Stage Information
Stage Diagrams
Full Stage Blank
Full Stage Measurements

Rigging


Detailed Measurements
- Proscenium Width: 36'
- Width upstage of proscenium: 50'
- Apron Width: 50'
- Total Depth: 43'
- Proscenium to downstage of thrust: 22'
- Proscenium to back wall: 21'
- Proscenium Height: 25'
- Height of ceiling above stage: 35'
- Horizontal distance from proscenium to balconies: 58'
- Throw from 2nd balcony spot position to proscenium: 98'
- Throw from 2nd balcony spot position to lip of stage: 79'
- Lighting Grid Trim: 28'
- Upstage Side Rail Trim: '
- Downstage Side Rail Trim: 10'
- Max out For ALL Fly Line sets: 40'
- Height above stage level of 1st Balcony: 14'
- Height above stage of 2nd Balcony: 26'
Power
A 400 amp three phase circuit is located on the backstage wall backstage right. The three phase panel has cam locks and no tails.
Arrangements must be made with the Bovard Production Office at least five (5) business days prior to the event.
TopRigging
Bovard has a brand-new automated rigging system, with winches and controls provided by Stage Technologies. More specs about the system are coming soon.
In the meantime, please check out the diagrams above or contact us for more information.
Support Spaces
Bovard has two dressing rooms available, one on each side of the stage.
- Stage Right:
- Capacity: 8 persons
- Amenities: Hot and cold water, Water fountain
- Stage Left:
- Capacity: 8 persons
- Amenities: Hot and cold water
Please see our stage diagram for exact locations.